| Micro controller operated Flow Meter to monitor and display flow rates and temperature. Once correctly adjusted it can also be used for mass flow measurements. Factory pre-set for air and water. |
| |
| Voltage rating: |
DC 24 V
|
| Input voltage: |
DC 24 V (19...32 V)
|
| Media: |
liquids gases
|
| Measuring range: |
water: 0.05...3 m/s oil: 0.05...5 m/s gases/air: 0.01...20 m/s
|
| Outputs/interfaces: |
analogue outputs: 0/4-20 mA or 0/2-10 V or 0/1-5 V signal outputs: relay or transistor outputs incl. pulse output
|
| Design: |
surface mounted version
|
| Process connection: |
calorimetric heads (CST, CSF, CSP) turbine heads (TST)
|
| Materials of monitoring head: |
Stainless steel 1.4571/AISI 316 Ti or Hastelloy alloy
|
| Temperature range electronic control unit: |
from +10 °C to +50 °C
|
| Temperature range monitoring head: |
from -40 °C to +130 °C
|
| Protection class electronic control unit: |
IP65
|
| Protection class monitoring head: |
IP67 (connector)
|