Safety in the air


No other industry sets higher standards with regard to safety than the aerospace industry.

Our well-proven, sophisticated aircraft circuit breakers protect cables and loads in all kinds of aircraft. We offer customer-specific solutions or system solutions or design new products and power distributions systems in co-operation with our customers.

It is our goal to offer you innovative solutions which help to save weight and costs in the aircraft.


Do you have any questions regarding this topic? Our specialists from the Aerospace division will be pleased to be of assistance!


Below please find a list of relevant products for your business field. By selecting products out of a category you will be able to directly compare their technical specifications.

Just click on “product comparison".


Type: 2-5700      Download
 
Dimensions
 
Internal connection diagrams
   
Single pole thermal circuit breaker with press-to-reset, tease-free, trip-free, snap action mechanism. Type 2-5700 can be supplied as a push-push switch/circuit breaker (R-type TO CBE to EN 60934 in press-to-reset configuration; S-type with push-push operation), threadneck panel mounting. Options include an additional unprotected circuit tap (-A3).
Approved to CBE standard EN 60934 (IEC 60934).
 
Voltage rating: 
  • AC 250 V
  • DC 28 V
  • UL/CSA: DC 50 V
Current ratings: 
from 0.05 A to 25 A  
Number of poles: 
single pole 
Mounting method: 
threadneck 
Terminal design: 
blade terminals 
screw terminals 
Actuation: 
push button 
Auxiliary contacts: 
without auxiliary contacts 
Water splash protection: 
with water splash protection 
without water splash protection 
Illumination: 
without illumination 
Typical life:
0.05...16 A 5,000 operations at 2 x IN, inductive
17...25 A 5,000 operations at 2 x IN, resistive
Interrupting capacity Icn:
0.05...2.5 A: 8 x IN
3...5 A: 20 x IN
6...12 A: 200 A (higher interrupting capacity available to special order)
13...25 A: 400 A
Approvals:
VDE, CSA, UL, SEV, CCC